2021

E 16.9 N Deflagration and endurance burning proof pressure and vacuum relief valve

KITO® VD/MC-IIA-…-A KITO® VD/MC-IIA-…-K Installations, explosion-proof and endurance burning proof for certain flammable liquids of the explosion group IIA with a maximum experimental safe gap (MESG) > 0.9 mm and an maximum operating temperature of 60 °C. As venting and breather device for fixed roof tanks to prevent inadmissible pressure and vacuum and to minimize […]

E 16.9 N Deflagration and endurance burning proof pressure and vacuum relief valve Read More »

E 16.9.2 N Deflagration and endurance burning proof pressure and vacuum relief valve

KITO® VD/MC-IIB3-… Installations, explosion-proof and endurance burning proof for certain flammable liquids of the explosion group IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm and an maximum operating temperature of 60 °C. As venting and breather device for fixed roof tanks to prevent inadmissible pressure and vacuum and to minimize gas losses

E 16.9.2 N Deflagration and endurance burning proof pressure and vacuum relief valve Read More »

E 16.9.1 N Deflagration and endurance burning proof pressure and vacuum relief valve

KITO® VD/MC-IIB1-… As an end-of-line flame arrester element to protect vent openings of storage tanks. Explosion and endurance burning proof for all inflammable liquids and vapors of explosion group IIB1 and also for alcohols with a maximum experimental safe gap (MESG) ≥ 0.85 mm and an maximum operating temperature of 60 °C. This device is

E 16.9.1 N Deflagration and endurance burning proof pressure and vacuum relief valve Read More »

E 16.8 N Deflagration and endurance burning proof pressure and vacuum relief valve

KITO® VD/MB-IIA-…/…-A KITO® VD/MB-IIA-…/…-K as end-of-line armature for venting apertures on tank installations, valve is explosion-proof and endurance-burning proof for certain flammable liquids of the explosion group IIA with a maximum experimental safe gap (MESG) > 0.9 and an maximum operating temperature of 60 °C. Used as venting and breather device for fixed roof tanks

E 16.8 N Deflagration and endurance burning proof pressure and vacuum relief valve Read More »

E 16.8.1 N Deflagration and endurance burning proof pressure and vacuum relief valve

KITO® VD/MB-IIB1-…/… End-of-line flame arrester, explosion and endurance burning proof for all inflammable liquids and vapors of explosion group IIB1 and also for alcohols with a maximum experimental safe gap (MESG) ≥ 0.85 mm and an maximum operating temperature of 60 °C. This device is not permitted to be installed in enclosed areas. Installation on

E 16.8.1 N Deflagration and endurance burning proof pressure and vacuum relief valve Read More »

E 15.2 N Deflagration and endurance burning proof pressure and vacuum relief valve

KITO® VD/KL-IIB1-…/… As an end-of-line flame arrester, explosion and endurance burning proof for all inflammable liquids and vapors of explosion group IIB1 and also for alcohols with a maximum experimental safe gap (MESG) ≥ 0.85 mm and an maximum operating temperature of 60 °C. Safety valve for out breathing pipes of storage tanks as a

E 15.2 N Deflagration and endurance burning proof pressure and vacuum relief valve Read More »

E 14 N Deflagration and endurance burning proof pressure and vacuum relief valve

KITO® VD/KL-IIA-…/…-A KITO® VD/KL-IIA-…/…-K As end-of-line armature for venting apertures on tank installations, valve is explosion-proof and endurance-burning proof for certain inflammable liquids. Used mainly as venting and breather device for fixed roof tanks to prevent inadmissible pressure and vacuum and to minimize unwelcome gas losses and inadmissible emissions. Approved for all materials of the

E 14 N Deflagration and endurance burning proof pressure and vacuum relief valve Read More »

Scroll to Top