G 32 N Bi-directional in-line detonation flame arrester

KITO® FS-Det4-IIC-…-1.2 Installation into pipelines as inline detonation flame arrester e. g. for the protection of ignition gas lines or measuring devices. Applicable for all materials of the explosion groups IIA1 up to IIC with a maximum experimental safe gap (MESG) < 0.5 mm. Operating from both sides, for a maximum operating pressure of 1.2 […]

G 32 N Bi-directional in-line detonation flame arrester Read More »

G 31 N Bi-directional in-line detonation flame arrester

KITO® FS-Det4-IIB3-…-1.2 Installation into pipelines as inline detonation flame arrester e. g. for the protection of ignition gas lines or measuring devices. Applicable for all materials of the explosion groups IIA1 up to IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm. Operating from both sides, for a maximum operating pressure of 1.2

G 31 N Bi-directional in-line detonation flame arrester Read More »

G 28 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® RG-Det4-IIC-… KITO® RG-Det4-IIC-…-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIC with a maximum experimental safe gap (MESG) < 0.5 mm. Bi-directionally working

G 28 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 28.0 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® RG-Det4-IIC-… KITO® RG-Det4-IIC-…-T (-TT) -design with flange connection – For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIC with a maximum experimental safe gap (MESG)

G 28.0 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 27 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® RG-Det4-IIB3-…-1.2 KITO® RG-Det4-IIB3-…-1.2-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experimental safe gap (MESG) ≥ 0.65 mm. Bi-directionally working

G 27 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 27.0 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® RG-Det4-IIB3-…-1.2 KITO® RG-Det4-IIB3-…-1.2-T (-TT) -design with flange connection- For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIB3 with a maximum experimental safe gap (MESG) ≥

G 27.0 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 26 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® RG-Det4-IIA-…-1.2 KITO® RG-Det4-IIA-…-1.2-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working

G 26 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 26.2 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® RG-Det4-IIA-…-4.5 KITO® RG-Det4-IIA-…-4.5-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG) > 0.9 mm. Bi-directionally working

G 26.2 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 26.0 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® RG-Det4-IIA-…-1.2 KITO® RG-Det4-IIA-…-1.2-T (-TT) – design with flange connection- For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIA with a maximum experimental safe gap (MESG)

G 26.0 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »

G 25 N Bi-directional in-line detonation flame arrester, short-time burning proof

KITO® EFA-Det4-IIC-…/…-1.2 KITO® EFA-Det4-IIC-…/…-1.2-T (-TT) For installation into pipes to the protection of vessels and components against stable detonation of flammable liquids and gases. Tested and approved as detonation flame arrester type 4. Approved for all substances of explosion groups IIA1 to IIC with a maximum experimental safe gap (MESG) < 0.5 mm. Bi-directionally working

G 25 N Bi-directional in-line detonation flame arrester, short-time burning proof Read More »